Products Description

|
Model |
I-05 WHP - rimless, wall hung, P-trap |
|
Dimensions |
517 × 360 × 365 mm (projection × width × ceramic body height) |
|
Fixing centres |
180 mm |
|
Outlet |
Rear, Ø102 mm spigot (AS 1172.1 range: 95–120 mm) |
|
Flush |
Dual flush 4.5/3 L nominal; measured 4.6 L full / 2.9 L reduced (report A18019) |
|
Water seal |
57 mm (AS 1172.1 minimum: 45 mm) |
|
Load rating |
Passed 400 kg / 60 min load safety test - no crack, split or craze |
|
Certification |
WaterMark WMK26227 (SAI Global, valid to 10 July 2027); 4-star water efficiency, tested to AS/NZS 6400:2016 |
|
Matched cistern |
G3004 concealed cistern (WaterMark WMKA21189) |
|
Lead time |
35-45days |
Certification Documents You Can Check Before Paying a Deposit
Certificate claims are the first thing Australian buyers ask a China factory to prove - so the full document pack goes out with the first quotation, not after the deposit. Three documents cover this model:



Rough-In and Frame Compatibility: the Numbers Your Plumber Will Ask For
Dimension mismatches - wrong set-out, wrong frame, wrong outlet position - are the most common way wall hung orders go wrong on site. Check these against your frame supplier's spec sheet before ordering:
Fixing centres: 180 mm, the common standard for in-wall cistern frames sold in Australia.
Outlet: rear, Ø102 mm spigot, connection depth over 32 mm - within the 95–120 mm range AS 1172.1 requires.
Projection: 517 mm from the finished wall; ceramic body height 365 mm. Final seat height is set by the frame installation, not the pan.
Tested as a set: report A18019 tested this pan together with the G3004 concealed cistern (WaterMark licence WMKA21189, Xiamen R&T), so pan-and-cistern compatibility is documented, not assumed.
The 400 kg load safety result matters most on commercial jobs, where fixture loading is a structural sign-off item. Installation must comply with AS/NZS 3500.2 and be carried out by a licensed plumber; installation instructions and the compliance documents ship with every order. Specifying for hospitality or multi-residential work? See the checklist for commercial wall hung toilets for hotel projects
Rimless Bowl and Glaze: What Factory QC Actually Checks
A rimless bowl has an open flush channel instead of a closed rim cavity. For housekeeping, that means no hidden rim to scrub. On the QC line, it means the flush pattern is fully visible during water testing - a blocked jet cannot hide under a rim.

FAQ
Q: How do I verify the WaterMark certification for this model?
A: Check certificate WMK26227 on the SAI Global product schedule - I-05 WHP is listed by name - rimless, P-trap, 4 stars - valid to 10 July 2027. The certificate PDF and test report A18019 are also sent with every quotation, so verification takes minutes, not emails.
Q: Does this pan need an in-wall frame, and which cistern does it fit?
A: Yes - every wall hung toilet requires a load-rated in-wall frame with a concealed cistern; the pan itself passed the 400 kg load safety test. It was type-tested with the G3004 concealed cistern (WaterMark WMKA21189) and fits standard frames with 180 mm fixing centres.
Q: What are the MOQ
A: 20
Q: Can you produce under our brand?
A: Yes - OEM covers the logo badge on the ceramic, seat branding, carton print and colour-box design. Branded samples are produced for sign-off before the bulk run, and artwork files are kept on record for repeat orders.
Hot Tags: wall hung toilet — watermark certified rimless wall hung pan, 4-star dual flush for trade & hotel projects (model i-05 whp), China wall hung toilet — watermark certified rimless wall hung pan, 4-star dual flush for trade & hotel projects (model i-05 whp) manufacturers, suppliers, factory, alpine one piece closet, my toilet keeps running, smart toilet with remote, wall hung toilet 2x4, wall mounted toilet seat with jet, washroom